Seismic Performance Comparison of Fixed Base and Isolated Base Steel Multi-Storey Building

Authors

  • Nwe Nwe Win Department of Civil Engineering, Mandalay Technological University, Mandalay, Myanmar
  • Zaw Min Htun Department of Civil Engineering, Mandalay Technological University, Mandalay, Myanmar

Keywords:

lead rubber bearing, Japan rubber, Myanmar rubber, response spectrum and nonlinear time history analyses, ETABS, FEMA P-58, PACT.

Abstract

This study presents the comparative study on seismic performance of with and without isolation in eight-storeyed hypothetic steel building located in Mandalay. The base isolation system that is utilized lead rubber bearing which made with Japan rubber and Myanmar rubbers (RSS-1 and RSS-3). In this study, base isolation devices are installed under each column between the building and the supporting foundation to support the building and to minimize the damage due to earthquake. In this study, comparative advantages for using lead rubber bearing isolation systems with various types of rubber are mainly investigated by performing response spectrum and nonlinear time history analyses. The comparison process has been carried out on performance of the structure with storey displacement, storey acceleration, and storey drift. In the analysis phase, nonlinear time history analyses at DBE and MCE levels are conducted in ETABS to obtain the related floor accelerations, interstorey drifts and storey displacement. In performance assessment phase, probable damage cost, repair time and rate of injuries are computed using fragility curves and FEMA P-58 methodology in Performance Assessment Calculation Tool (PACT). Damage cost, repair time and rate of injuries are computed for each building at seismic demand level and the results are compared. According to investigation conducted, it can be inferred that RSS-3 is more effective than RSS-1 at DBE while RSS-1 is better than RSS-3 at MCE levels.

References

[1] Greg T.E. Kelly, “Base isolation of structures: Design guidelines”, Wellington, New Zealand: Holmes Consulting Group Ltd, 2001.
[2] N.Naeim & J.M.Kelly,“Design of Seismic Isolated Structures from Theory to Practice”, 1999
[3] I. Micheli,S. Cardini,A. Colaiuda, P. Turroni, “Investigation upon the dynamic structural response of a nuclear plant on aseismic isolating devices”, Nuclrar Engineering and Design, 228 (2004) 319-343.
[4] Kunde, M.C. and Jangid, R.S, “Seismic behaviour of isolated bridges: A State- of the Art Review,” Electronic Journal of Structural Engineering, Australia, Vol.3, pp.140-170, 2003.
[5] Buckle, I.G. and Mayes, R.L., “Seismic isolation: history, application and performance: A Word Overview”, Earthquake Spectra, Vol.6, pp.161-202, 1990.
[6] Fragiacomo, M., Rajgelj, S., and Cimadom, F., “Design of Bilinear Hysteretic Isolation Systems”, Earthquake Engineering and Structural Dynamics, Vol.32, No.9, pp.1333-1352, 2003.
[7] H.P.Santhosh, K.S. Manjunath, and K.S.Kumar, “Seismic analysis of low to medium rise building for base isolation”, International Journal of Research in Engineering and Technology, 2013.
[8] N.Torunbalci, G.Ozpalnlar, “Earthquake response analysis of mid-storey buildings isolated with various seismic isolation techniques”, 14th world conference on Earthquake Engineering, vol.Oct.12-17, Beijing, China, 2008.
[9] Robinson, W.H. Lead-rubber hysteretic bearings suitable for protecting structures during earthquakes, Earthquake. Engineering. Structural Dynamic, 10, 593–604, 1982.
[10] S.M.Dhawade, “Comparative study for seismic performance of base isolated & fixed base RC frame structure”, International Journal of civil engineering research, vol.5, pp.183-190, 2014.
[11] N.R.Chandak, “Effect of base isolation on the response of reinforced concrete building”, Journal of civil engineering Research, vol. 3(4), pp. 135-142, 2013.
[12] Young-Sang Kim-, “Study on the Effective Stiffness of Base Isolation System for Reducing Acceleration and Displacement Responses”, Journal of the Korean Nuclear society, Volume 31, Number 6, pp.586-594, December 1999.
[13] T.E. Kelly, Base isolation of structures: Design guidelines. Wellington, New Zealand: Holmes Consulting Group Ltd, 2001.
[14] Applied Technology Council (ATC). FEMA P-58: Seismic Performance Assessment of Buildings, Volume 2 – Implementation Guide. (2012). 26 March 2013.

Downloads

Published

2017-04-06

How to Cite

Win, N. N., & Htun, Z. M. (2017). Seismic Performance Comparison of Fixed Base and Isolated Base Steel Multi-Storey Building. American Scientific Research Journal for Engineering, Technology, and Sciences, 29(1), 348–370. Retrieved from https://asrjetsjournal.org/index.php/American_Scientific_Journal/article/view/2816

Issue

Section

Articles